Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument, with laptop computer
Applied Biosystems® 7500 Fast Dx Real-Time PCR Instrument, with laptop computer

Specifications
General Specifications
Platform: |
7500 Fast Dx System
|
Format: |
96-well plate,
8-well strips
|
Optics: |
Five excitation and five emission filters,
Halogen light source,
CCD Camera
|
Weight: |
34 kg (75 lb)
|
Capacity: |
12 x 8-tube strips,
1 x 96-well plate (Fast)
|
Run Time: |
36 min (Fast),
<2 hrs (Standard)
|
Precision: |
Can differentiate between 5000 and 1000 template copies with 99.7% confidence
|
Ramp Rate: |
Fast Mode: 3.5°:C/sec,
Standard Mode: 1.6°C/sec
|
Dimensions: |
34 cm (13.39 in) (W) x 49 cm (19.29 in) (H) x 45 cm (17.72 in) (D)
|
Throughput: |
4 to 5 96-well plates per day
|
Sensitivity: |
Down to 1 copy of human RNAse P gene
|
Product Size: |
1 system
|
Dynamic Range: |
9 logs of linear dynamic range
|
Calibrated Dye: |
JOE,
VIC,
SYBR Green,
Cy5,
Texas Red,
NED,
ROX,
TAMRA,
Cy3,
FAM
|
Reaction Speed: |
Standard,
Fast
|
External Computer: |
Laptop computer provided
|
Temperature Range: |
4-94°C
|
Temperature Accuracy: |
±0.5°C of display temperature
|
Passive Reference Dye: |
ROX (Pre-mixed),
ROX (Separate Tube),
Other Passive Reference Dye
|
Reaction Volume Range: |
10-30 µl
|
Temperature Uniformity: |
±1°C
|
Thermal Cycling System: |
Peltier-based
|
7500 Fast Real-Time PCR System, desktop
7500 Fast Real-Time PCR System, desktop
Specifications
General Specifications
Platform: |
7500 Fast System
|
Format: |
96-well plate
|
Optics: |
Tungsten-Halogen source,
Five excitation and five emission filters,
CCD Camera
|
Weight: |
34 kg (75 lb)
|
Capacity: |
1 x 96-well plate (Fast)
|
Run Time: |
36 min (Fast),
<2 hrs (Standard)
|
Precision: |
Can differentiate between 5000 and 1000 template copies with 99.7% confidence
|
Ramp Rate: |
Fast Mode: 3.5°:C/sec,
Standard Mode: 1.6°C/sec
|
Dimensions: |
34 cm (13.39 in) (W) x 49 cm (19.29 in) (H) x 45 cm (17.72 in) (D)
|
Throughput: |
4 to 5 96-well plates per day
|
Sensitivity: |
Down to 1 copy of human RNAse P gene
|
Product Size: |
1 system
|
Dynamic Range: |
9 logs of linear dynamic range
|
Calibrated Dye: |
JOE,
SYBR Green 1,
VIC,
Cy3,
Cy5,
Texas Red,
NED,
ROX,
TAMRA,
FAM
|
Reaction Speed: |
Standard,
Fast
|
External Computer: |
Dell Tower provided
|
Temperature Range: |
4-100°C
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Temperature Accuracy: |
±0.25°C of display temperature
|
Passive Reference Dye: |
ROX (Pre-mixed),
Other Passive Reference Dye,
ROX (Separate Tube)
|
Reaction Volume Range: |
5-30 µl
|
Temperature Uniformity: |
±0.5°C
|
Thermal Cycling System: |
Peltier-based
|
3500 Genetic Analyzer for Resequencing & Fragment Analysis
3500 Genetic Analyzer for Resequencing & Fragment Analysis

Specifications
General Specifications
Platform: |
3500 Genetic Analyzer
|
Format: |
96-well plate,
8-well strips
|
Weight: |
82 kg (approximately)
|
Throughput: |
Up to 424 samples per day (using run module HID36 POP-7)
|
Read Length: |
≥850 bp using a 50cm capillary and POP-7
|
Product Size: |
1 system
|
Current Limit: |
15 amps
|
Plan Duration: |
Service Installation and Application Training Included,
1 Year Limited Warranty on Parts and Labor
|
Voltage Limit: |
Electrophoresis Voltage - Up to 20 kV
|
Capillary Length: |
50 cm,
36 cm
|
Operating System: |
Windows Vista (Service Pack 1)
|
Analysis Software: |
GeneMapper® Software
|
External Computer: |
Operating System: Windows® Vista® SP1,
Installed RAM: 2GB,
Hard Drive: 1 x 80GB 7200 RPM SATA 3.0Gb⁄s and 8MB Data Burst Cache,
Hardware: Pentium® IV Processor - 1.86 GHz Processor
|
Compatible Polymers: |
POP-7,
POP-6,
POP-4
|
Compatible Products: |
3500 Genetic Analyzer Capillary Array (50 cm),
3500 Genetic Analyzer Capillary Array (36 cm),
POP-6™ Polymer for 3500⁄3500xL Genetic Analyzers,
POP-7™ Polymer for 3500⁄3500xL Genetic Analyzers,
POP-4™ Polymer for 3500⁄3500xL Genetic Analyzers
|
Polymer Consumption: |
Replace at earliest of 7 days⁄384 samples⁄60 Injections (384-sample pouches),
Replace at earliest of 7 days⁄960 samples⁄120 Injections (960-sample pouches)
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Number of Capillaries: |
8 Capillaries
|
Operating Environment: |
Room temp: <2° fluctuation during runs,
Humidity: 20%-80% (non-condensing),
Temperature: 15°C-30°C
|
ProFlex™ 2 x 384-well PCR System
ProFlex™ 2 x 384-well PCR System

Specifications
General Specifications
New Product: |
New additions to lifetechnologies.com
|
Platform: |
ProFlex™ PCR System
|
Format: |
384-well plate
|
Capacity: |
2 x 384-well plate,
768 x 0.02 ml tubes
|
High Throughput Compatibility: |
High Throughput-Compatible
|
Weight: |
18.75 kg (41 lb)
|
Ramp Rate: |
Max Sample Ramp Rate 1.6 °C⁄Sec,
Max Block Ramp Rate 3.0°C⁄Sec
|
Dimensions: |
Height: 27 cm (10.6 in), Width: 33 cm (13 in), Depth: 56.5 cm (22 in)
|
Product Size: |
1 instrument
|
Reaction Speed: |
Fast,
Standard
|
Program Features: |
Auto re-start (after power outages),
Program overwrite protection
|
Display Interface: |
Touchscreen (8.4 in. TFT LCD)
|
Instrument Memory: |
USB and On-board
|
Temperature Range: |
0 to 100.0 °C
|
Power Requirements: |
100-240V, 50-60 Hz Max: 950 VA
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Temperature Accuracy: |
±0.25°C (35°C to 99.9°C)
|
Temperature Uniformity: |
<0.5 °C (20 sec after reaching 95 °C)
|
ProFlex™ 2 x flat PCR System
ProFlex™ 2 x flat PCR System

Specifications
General Specifications
Platform: |
ProFlex™ PCR System
|
Format: |
2 X Flat Block for OpenArray® Plates
|
High Throughput Compatibility: |
High Throughput-Compatible
|
Weight: |
18.75 kg (41 lb)
|
Ramp Rate: |
Max Block Ramp Rate 2.0 °C⁄Sec
|
Dimensions: |
33 cm (13 in) (W) x 27 cm (11 in) (H) x 57 cm (22 in) (D)
|
Block Format: |
Interchangeable
|
Product Size: |
1 instrument
|
Reaction Speed: |
Fast or Standard
|
Program Features: |
Auto re-start (after power outages),
Program overwrite protection
|
Display Interface: |
Touchscreen (8.4 in. TFT LCD)
|
Instrument Memory: |
USB and On-board
|
Temperature Range: |
0 to 100.0 °C
|
Power Requirements: |
100-240V, 50-60 Hz Max: 950 VA
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Temperature Accuracy: |
±0.25°C (35°C to 99.9°C)
|
Reaction Volume Range: |
33 nl (± 1 nl)
|
Temperature Uniformity: |
<0.5 °C (20 sec after reaching 95 °C)
|
ProFlex™ 2 x 96-well PCR System
ProFlex™ 2 x 96-well PCR System
Specifications
General Specifications
Platform: |
ProFlex™ PCR System
|
Format: |
96-well plate,
0.2 ml tubes,
12-strip wells
|
Capacity: |
2 x 96-well x 0.2 ml tubes
|
High Throughput Compatibility: |
High Throughput-Compatible
|
Weight: |
18.75 kg (41 lb)
|
Ramp Rate: |
Max Sample Ramp Rate 1.6 °C⁄Sec,
Max Block Ramp Rate 3.0°C⁄Sec
|
Dimensions: |
33 cm (13 in) (W) x 27 cm (11 in) (H) x 57 cm (22 in) (D)
|
Block Format: |
Interchangeable
|
Product Size: |
1 instrument
|
Reaction Speed: |
Fast or Standard
|
Program Features: |
Auto re-start (after power outages),
Program overwrite protection
|
Display Interface: |
Touchscreen (8.4 in. TFT LCD)
|
Instrument Memory: |
USB and On-board
|
Temperature Range: |
0 to 100.0 °C
|
Power Requirements: |
100-240V, 50-60 Hz Max: 950 VA
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Temperature Accuracy: |
±0.25°C (35°C to 99.9°C)
|
Reaction Volume Range: |
10-100 µl
|
Temperature Uniformity: |
<0.5 °C (20 sec after reaching 95 °C)
|
ProFlex™ 3 x 32-well PCR System
ProFlex™ 3 x 32-well PCR System
Specifications
General Specifications
Platform: |
ProFlex™ PCR System
|
Format: |
12-strip wells,
0.2 ml tubes
|
Capacity: |
3 x 32-well x 0.2 ml tubes
|
High Throughput Compatibility: |
High Throughput-Compatible
|
Weight: |
18.75 kg (41 lb)
|
Ramp Rate: |
Max Sample Ramp Rate 4.4 °C⁄Sec,
Max Block Ramp Rate 6.0 °C⁄Sec
|
Dimensions: |
33 cm (13 in) (W) x 27 cm (11 in) (H) x 57 cm (22 in) (D)
|
Block Format: |
Interchangeable
|
Product Size: |
1 instrument
|
Reaction Speed: |
Fast or Standard
|
Program Features: |
Auto re-start (after power outages),
Program overwrite protection
|
Display Interface: |
Touchscreen (8.4 in. TFT LCD)
|
Instrument Memory: |
USB and On-board
|
Temperature Range: |
0 to 100.0 °C
|
Power Requirements: |
100-240V, 50-60 Hz Max: 950 VA
|
Regulatory Statement: |
For Research Use Only. Not for use in diagnostic procedures.
|
Temperature Accuracy: |
±0.25°C (35°C to 99.9°C)
|
Reaction Volume Range: |
10-80 µl
|
Temperature Uniformity: |
<0.5 °C (20 sec after reaching 95 °C)